DOWN DOC Triclos ® chromium and trivalent chromium plating process
Name: Triclos ® chromium and trivalent chromium plating process
Origin: Germany
Packing: 25Kg/Dr
Origin: Germany
Packing: 25Kg/Dr
I、Features
1. Environmentally friendly products, hexavalent chromium-free, simple and wastewater treatment.
2. Uniform color, appearance, with good coverage ability and the ability to have degrees.
3. Bath does not contain organic solvents; of chloride and sulfate of good tolerance.
4. Electroplating when power would not have adverse consequences, the deposition rate faster than the hexavalent chromium.
5. OPASS Germany used to provide the graphite anode, improve quality and increase the stability of the bath.
2. Uniform color, appearance, with good coverage ability and the ability to have degrees.
3. Bath does not contain organic solvents; of chloride and sulfate of good tolerance.
4. Electroplating when power would not have adverse consequences, the deposition rate faster than the hexavalent chromium.
5. OPASS Germany used to provide the graphite anode, improve quality and increase the stability of the bath.
II、Bath composition and operating conditions
1.the composition of the solution
Raw materials and operating conditions
|
Range
|
Standard Range
|
TCR-MX Complex salt
|
400-450 g / l
|
425 g/ l
|
TCR-CAT stabilizer
|
55-75 ml / l
|
65 ml / l
|
TCR-RT wetting agent
|
2-4 ml / l
|
3 ml / l
|
TCR-CS mixture of chromium
|
1-2 ml / l
|
1.5 ml / l
|
TCR-BK by black agents
|
20-30 ml / l
|
25 ml / l
|
2. Operating conditions
Trivalent chromium
|
20-23 g/l
|
22 g/l
|
PH
|
2.3-2.9
|
2.5-2.7
|
Temperature
|
30-40℃
|
35℃
|
The proportion of bath
|
1.20-1.24
|
1.22
|
Cathode current density
|
10-22amp / square decimeter
|
16amp / square decimeter
|
Anode current density
|
2-5amp / square decimeter
|
2amp / square decimeter
|
Anode: Cathode(area ratio)
|
1.5-2.0︰1
|
|
Current
|
direct current,Corrugated rate﹤10%
|
|
Voltage
|
9-12V
|
|
Deposition rate
|
0.15-0.25 micron / min
(10.8 amp / square decimeter)
|