DOWN DOC Tritonx ® trivalent chromium white chrome plating process
Name: Tritonx ® trivalent chromium white chrome plating process
Origin: Germany
Packing: 25Kg/Dr
I、Features
1. Environmentally friendly products, hexavalent chromium-free, simple and wastewater treatment.
2. Uniform color, appearance, with good coverage ability and the ability to have degrees.
3. Bath does not contain organic solvents; of chloride and sulfate of good tolerance.
4. Electroplating power when no adverse effects, the deposition rate faster than the hexavalent chromium.
5. OPASS Germany used to provide the graphite anode, improve quality and increase the stability of the bath.
2. Uniform color, appearance, with good coverage ability and the ability to have degrees.
3. Bath does not contain organic solvents; of chloride and sulfate of good tolerance.
4. Electroplating power when no adverse effects, the deposition rate faster than the hexavalent chromium.
5. OPASS Germany used to provide the graphite anode, improve quality and increase the stability of the bath.
II、Bath composition and operating conditions
1.the composition of the solution
Raw materials and operating conditions
|
Range
|
Standard Range
|
TCR-MX Complex salt
|
400-450 g / l
|
425 g/ l
|
TCR-CAT stabilizer
|
55-75ml / l
|
65 ml / l
|
TCR-RT wetting agent
|
2-4 ml / l
|
3 ml / l
|
TCR-CS mixture of chromium
|
1-2 ml / l
|
1.5 ml / l
|
2. Operating conditions
Trivalent chromium
|
20-23 g/l
|
22 g/l
|
PH
|
2.3-2.9
|
2.5-2.7
|
Temperature
|
30-40℃
|
35℃
|
The proportion of bath
|
1.20-1.24
|
1.22
|
Cathode current density
|
10-22amp / square decimeter
|
16amp / square decimeter
|
Anode current density
|
2-5amp / square decimeter
|
2amp / square decimeter
|
Anode: Cathode(area ratio)
|
1.5-2.0︰1
|
|
Current
|
direct current,Corrugated rate﹤10%
|
|
Voltage
|
9-12V
|
|
Deposition rate
|
0.15-0.25 micron / min
(10.8 amp / square decimeter)
|